Anso, Juan; Balmer, Thomas W.; Jegge, Yves; Kalvoy, Havard; Bell, Brett J.; Dür, Cilgia; Calvo, Enric M.; Williamson, Tom M.; Gerber, Nicolas; Ferrario, Damien; Forterre, Frank; Büchler, Philippe; Stahel, Andreas; Caversaccio, Marco D.; Weber, Stefan; Gavaghan, Kate A. (2019). Electrical Impedance to Assess Facial Nerve Proximity during Robotic Cochlear Implantation IEEE Transactions on Biomedical Engineering, 66(1), pp. 237-245. IEEE 10.1109/TBME.2018.2830303
Text
WyssAnso2018.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (3MB) | Request a copy |
Reported studies pertaining to needle guidance suggest that tissue impedance available from neuromonitoring systems can be used to discriminate nerve tissue proximity. In this pilot study, the existence of a relationship between intraoperative electrical impedance and tissue density, estimated from computer tomography (CT) images, is evaluated in the mastoid bone of in vivo sheep. In five subjects, nine trajectories were drilled using an image-guided surgical robot. Per trajectory, five measurement points near the facial nerve were accessed and electrical impedance was measured (ࣘ1 KHz) using a multipolar electrode probe. Micro-CT was used postoperatively to measure the distances from the drilled trajectories to the facial nerve. Tissue density was determined from coregistered preoperative CT images and, following sensitivity field modeling of the measuring tip, tissue resistivity was calculated. The relationship between impedance and density was determined for 29 trajectories passing or intersecting the facial nerve. A monotonic decrease in impedance magnitude was observed in all trajectories with a drill axis intersecting the facial nerve. Mean tissue densities intersecting with the facial nerve (971–1161 HU) were different (p <0.01) from those along safe trajectories passing the nerve (1194–1449 HU). However, mean resistivity values of trajectories intersecting the facial nerve (14–24 Ωm) were similar to those of safe passing trajectories (17–23 Ωm). The determined relationship between tissue density and electrical impedance during neuromonitoring of the facial nerve suggests that impedance spectroscopy may be used to increase the accuracy of tissue discrimination, and ultimately improve nerve safety distance assessment in the future.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
School of Engineering and Computer Science > Institute for Human Centered Engineering (HUCE) School of Engineering and Computer Science |
Name: |
Anso, Juan; Balmer, Thomas W.; Jegge, Yves; Kalvoy, Havard; Bell, Brett J.; Dür, Cilgia; Calvo, Enric M.; Williamson, Tom M.; Gerber, Nicolas; Ferrario, Damien; Forterre, Frank; Büchler, Philippe; Stahel, Andreas; Caversaccio, Marco D.; Weber, Stefan and Gavaghan, Kate A. |
ISSN: |
1558-2531 |
Publisher: |
IEEE |
Language: |
English |
Submitter: |
Andreas Stahel |
Date Deposited: |
26 Nov 2019 09:06 |
Last Modified: |
29 Jan 2020 11:31 |
Publisher DOI: |
10.1109/TBME.2018.2830303 |
ARBOR DOI: |
10.24451/arbor.9030 |
URI: |
https://arbor.bfh.ch/id/eprint/9030 |