Comparison between Predicted and Measured Moisture Content and Climate in 12 Monitored Timber Structures in Switzerland

Schiere, Marcus; Franke, Bettina; Franke, Steffen; Müller, Andreas (2021). Comparison between Predicted and Measured Moisture Content and Climate in 12 Monitored Timber Structures in Switzerland Buildings 2021, 11, pp. 1-17. MDPI https://doi.org/10.3390/buildings11050181

[img]
Preview
Text
Schiere Franke Franke Müller 2021 Comparison betwenn predicted and measured moisture content Journal Paper.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (3MB) | Preview

Wood is a hygroscopic material that primarily adapts its moisture content to the surrounding relative humidity. The climate in a structure or building depends on the building type and the region the structure is located in. In this study, the effect of region on the moisture content of wood was investigated. Measurements taken in 12 ventilated timber structures were compared to the theoretical equilibrium moisture content calculated from the relative humidity and temperature in 107 meteorological stations across Switzerland. The monitored load-bearing elements were made of softwood and protected from the direct impact of weather. The climatic conditions around the Alps, a mountain range that runs from France to Austria and crosses Switzerland, can be divided into the following three different regions: (1) south of the Alps, where the climate is affected mainly by the Mediterranean sea; (2) north of the Alps, where the climate is affected by the Atlantic Ocean; and (3) the inner Alps, where the climate is considered to be relatively dry. The climatic conditions of the three separate regions were reflected in the measurements made in the monitored timber structures. Differences between the regions were quantified. The moisture content and relative humidity, similarly to temperature, depended on altitude (above sea level).

Item Type:

Journal Article (Original Article)

Division/Institute:

School of Architecture, Wood and Civil Engineering
School of Architecture, Wood and Civil Engineering > Institute for Timber Construction, Structures and Architecture
School of Architecture, Wood and Civil Engineering > Institute for Timber Construction, Structures and Architecture > Built Environment and Historic Preservation
School of Architecture, Wood and Civil Engineering > Institute for Timber Construction, Structures and Architecture > Timber Construction
School of Architecture, Wood and Civil Engineering > Institute for Timber Construction, Structures and Architecture > Structural Engineering

Name:

Schiere, Marcus;
Franke, Bettina0000-0002-8087-9347;
Franke, Steffen0000-0003-2430-8491 and
Müller, Andreas

Subjects:

T Technology > T Technology (General)
T Technology > TG Bridge engineering
T Technology > TH Building construction

Publisher:

MDPI

Language:

English

Submitter:

Corinne Amstutz Hugi

Date Deposited:

17 Jan 2022 14:33

Last Modified:

17 Jan 2022 14:33

Publisher DOI:

https://doi.org/10.3390/buildings11050181

Uncontrolled Keywords:

moisture content climate meteorological data building standards monitoring

ARBOR DOI:

10.24451/arbor.16193

URI:

https://arbor.bfh.ch/id/eprint/16193

Actions (login required)

View Item View Item
Provide Feedback