Corneal absorption spectra in the deep UV range

Inniger, Dominik; Poretti, Alessio; Ryser, Manuel; Meier, Christoph; Rathjen, Christian; Feurer, Thomas (2022). Corneal absorption spectra in the deep UV range Jornal of Biomedical Optics, 27(2), pp. 1-11. S P I E - International Society for Optical Engineering 10.1117/1.JBO.27.2.025004

[img]
Preview
Text
025004_1.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (2MB) | Preview

Significance: Refractive surgery in ophthalmology uses pulsed lasers at 193, 210, or 213 nm. The reason is that most molecular constituents of cornea absorb strongly in this wavelength range. Precise refractive surgery via ablation requires an accurate knowledge of the absorption coefficient at the relevant wavelengths. Yet, the absorption coefficients of corneal tissue reported in literature vary by almost an order of magnitude; moreover, they were measured mostly at the wavelengths mentioned earlier. Aim: By measuring the corneal absorption coefficient of intact eyeballs stored at different environmental conditions, prepared by following different procedures, and as a function of postmortem time, we determine the absorption coefficient for the entire wavelength range between 185 and 250 nm for as close as possible to in-vivo conditions. Approach: We use a specially designed UVellipsometer to measure refractive index and absorption coefficient. Specifically, we investigate the temporal evolution of refractive index and absorption coefficient after enucleation of the eyeballs under different environmental conditions and preparation procedures. Results: Our measurements provide accurate values for refractive index as well as absorption coefficient of cornea in the wavelength range between 185 and 250 nm. We find that the absorption coefficient decreases with time and that neither storage conditions nor preparation procedures but a continuous degeneration of the cornea is responsible for the observed time evolution. We use the measured time evolution to extrapolate refractive index and absorption coefficient to in-vivo conditions. Conclusion: Our measurements of the close to in-vivo absorption coefficient of cornea between 185 and 250 nm allow for a better understanding and modeling of refractive cornea surgery, also at other than the three commonly used wavelengths. In the future, this may be relevant when new pulsed laser sources with other wavelengths become available.

Item Type:

Journal Article (Original Article)

Division/Institute:

School of Engineering and Computer Science > Institute for Human Centered Engineering (HUCE) > HUCE / Laboratory for Optics
School of Engineering and Computer Science

Name:

Inniger, Dominik;
Poretti, Alessio;
Ryser, Manuel;
Meier, Christoph;
Rathjen, Christian and
Feurer, Thomas

Subjects:

Q Science > QC Physics

ISSN:

1083-3668

Publisher:

S P I E - International Society for Optical Engineering

Language:

English

Submitter:

Christoph Meier

Date Deposited:

07 Mar 2022 15:45

Last Modified:

07 Mar 2022 15:45

Publisher DOI:

10.1117/1.JBO.27.2.025004

Uncontrolled Keywords:

absorption; ultraviolet; ellipsometry; refractive index; ophthalmology

ARBOR DOI:

10.24451/arbor.16669

URI:

https://arbor.bfh.ch/id/eprint/16669