Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Explainable AI for Intraoperative Motor-Evoked Potential Muscle Classification in Neurosurgery: Bicentric Retrospective Study
 

Explainable AI for Intraoperative Motor-Evoked Potential Muscle Classification in Neurosurgery: Bicentric Retrospective Study

URI
https://arbor.bfh.ch/handle/arbor/46328
Version
Published
Identifiers
10.2196/63937
Date Issued
2025-03-24
Author(s)
Parduzi, Qendresa
Wermelinger, Jonathan
Koller, Simon Domingo
Sariyar, Murat  
Schneider, Ulf
Raabe, Andreas
Seidel, Kathleen
Type
Article
Language
English
Subjects

artificial intelligen...

convolutional neural ...

deep learning

explainability

intraoperative neurom...

machine learning

medical informatics

monitoring

motor

motor evoked potentia...

neurophysiological

neurosurgery

orthopedic

personalized medicine...

random forest

Abstract
Background: Intraoperative neurophysiological monitoring (IONM) guides the surgeon in ensuring motor pathway integrity during high-risk neurosurgical and orthopedic procedures. Although motor-evoked potentials (MEPs) are valuable for predicting motor outcomes, the key features of predictive signals are not well understood, and standardized warning criteria are lacking. Developing a muscle identification prediction model could increase patient safety while allowing the exploration of relevant features for the task.

Objective: The aim of this study is to expand the development of machine learning (ML) methods for muscle classification and evaluate them in a bicentric setup. Further, we aim to identify key features of MEP signals that contribute to accurate muscle classification using explainable artificial intelligence (XAI) techniques.

Methods: This study used ML and deep learning models, specifically random forest (RF) classifiers and convolutional neural networks (CNNs), to classify MEP signals from routine supratentorial neurosurgical procedures from two medical centers according to muscle identity of four muscles (extensor digitorum, abductor pollicis brevis, tibialis anterior, and abductor hallucis). The algorithms were trained and validated on a total of 36,992 MEPs from 151 surgeries in one center, and they were tested on 24,298 MEPs from 58 surgeries from the other center. Depending on the algorithm, time-series, feature-engineered, and time-frequency representations of the MEP data were used. XAI techniques, specifically Shapley Additive Explanation (SHAP) values and gradient class activation maps (Grad-CAM), were implemented to identify important signal features.

Results: High classification accuracy was achieved with the RF classifier, reaching 87.9% accuracy on the validation set and 80% accuracy on the test set. The 1D- and 2D-CNNs demonstrated comparably strong performance. Our XAI findings indicate that frequency components and peak latencies are crucial for accurate MEP classification, providing insights that could inform intraoperative warning criteria.

Conclusions: This study demonstrates the effectiveness of ML techniques and the importance of XAI in enhancing trust in and reliability of artificial intelligence-driven IONM applications. Further, it may help to identify new intrinsic features of MEP signals so far overlooked in conventional warning criteria. By reducing the risk of muscle mislabeling and by providing the basis for possible new warning criteria, this study may help to increase patient safety during surgical procedures.
DOI
https://doi.org/10.24451/arbor.12694
Publisher DOI
10.2196/63937
Journal or Serie
Journal of medical Internet research
Journal or Serie
Journal of Medical Internet Research
ISSN
1438-8871
Publisher URL
https://www.jmir.org/2025/1/e63937
Organization
Technik und Informatik  
Institut für Optimierung und Datenanalyse IODA  
Volume
27
Publisher
JMIR Publications
Submitter
Sariyar, Murat
Citation apa
Parduzi, Q., Wermelinger, J., Koller, S. D., Sariyar, M., Schneider, U., Raabe, A., & Seidel, K. (2025). Explainable AI for Intraoperative Motor-Evoked Potential Muscle Classification in Neurosurgery: Bicentric Retrospective Study. In Journal of Medical Internet Research (Vol. 27). JMIR Publications. https://doi.org/10.24451/arbor.12694
File(s)
Loading...
Thumbnail Image
Download

open access

Name

jmir-2025-1-e63937.pdf

License
Attribution 4.0 International
Version
published
Size

811.59 KB

Format

Adobe PDF

Checksum (MD5)

e5a8d0a7d3250600c0880639d8143d5e

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution