Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers
 

The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers

URI
https://arbor.bfh.ch/handle/arbor/39239
Version
Published
Date Issued
2018
Author(s)
Wyss, Thomas  
Beeler, Nadja
Roos, Lilian
Delves, Simon K.
Veenstra, Bertil J.
Friedl, Karl
Buller, Mark J.
Type
Article
Language
English
Subjects

Wearable devices Devi...

Abstract
OCCUPATIONAL APPLICATIONS We investigated the wearing comfort of nine devices for monitoring physical activity in a military context. In general, the questionnaire-based survey revealed that the devices were highly acceptable. For long-term monitoring of physical activity in soldiers (>5 days), slightly more participants (85.2%) found that sensors not located at the chest would be more acceptable compared to the chest-worn devices (66.7%). More specifically, our results suggest that devices placed on or around the upper arm, the hip, or the shoe will be preferred over devices worn around the wrist or on or around the chest in a military context. The placement of physical activity monitoring devices around the chest, in particular, can be expected to lead to discomfort due to incompatibilities with military equipment.
TECHNICAL ABSTRACT Background: Military organizations use body-worn devices for ambulatory monitoring of physical activity in soldiers. However, little is known regarding the wearing comfort and acceptability of ambulatory monitoring devices as used in the military context. Purpose: To investigate the wearing comfort and acceptability of nine body-worn devices for monitoring physical activity in soldiers. Methods: A total of 27 male volunteers wore three randomly assigned devices simultaneously for one day of basic military training. The participants then completed a questionnaire designed to assess comfort and acceptability. Results: Devices worn on or around the chest were associated with lower wearing comfort and acceptability scores (overall scores of 59.7, 70.8, and 80.9 for Hidalgo EQ02, TICKR X, and ActiHeart, respectively). Devices worn around the wrist, Mio FUSE (80.9), GENEActiv (81.3), and fenix 3 (85.3), had mid-range scores. The highest scores were obtained for the devices Blue Thunder, worn on the shoe (85.5), Axiamote PADIS 2.0, worn on the hip and the backpack (88.9), and Everion, worn on the upper arm (90.1). Conclusions: Body-worn devices for monitoring physical activity are well-accepted in soldiers. The differences between the devices were small for several parameters. Nevertheless, devices that are attached to, or around, the chest, were typically perceived as having a slightly more negative impact on the body. Both wrist- and chest-worn devices received some reports of interfering with military equipment or military tasks.
DOI
10.24451/arbor.10999
https://doi.org/10.24451/arbor.10999
Publisher DOI
10.1080/24725838.2018.1435431
Journal or Serie
IISE Transactions on Occupational Ergonomics and Human Factors
ISSN
2472-5838 (Print) 2472-5846 (Online)
Publisher URL
https://www.tandfonline.com/doi/full/10.1080/24725838.2018.1435431
Related URL
https://www.tandfonline.com/doi/pdf/10.1080/24725838.2018.1435431?needAccess=true publication
Organization
Monitoring  
Volume
6
Issue
1
Publisher
Taylor & Francis
Submitter
ServiceAccount
Citation apa
Wyss, T., Beeler, N., Roos, L., Delves, S. K., Veenstra, B. J., Friedl, K., & Buller, M. J. (2018). The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers. In IISE Transactions on Occupational Ergonomics and Human Factors (Vol. 6, Issue 1, pp. 1–10). Taylor & Francis. https://doi.org/10.24451/arbor.10999
File(s)
Loading...
Thumbnail Image

restricted

Name

Wyss_2018_The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers.pdf

License
Publisher
Version
published
Size

602.5 KB

Format

Adobe PDF

Checksum (MD5)

d632d642ce9a860b4e35371f52ea4cfd

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution