Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Comparing the Validity and Output of the GT1M and GT3X Accelerometer in 5- to 9-Year-Old Children
 

Comparing the Validity and Output of the GT1M and GT3X Accelerometer in 5- to 9-Year-Old Children

URI
https://arbor.bfh.ch/handle/arbor/31978
Version
Published
Date Issued
2013
Author(s)
Jimmy, Gerda
Seiler, Roland
Mäder, Urs  
Type
Article
Language
English
Subjects

Physical activity ass...

Abstract
Abstract The purpose of this study was to compare the validity and output of the biaxial ActiGraph GT1M and the triaxial GT3X (ActiGraph, LLC, Pensacola, FL, USA) accelerometer in 5- to 9-year-old children. Thirty-two children wore the two monitors while their energy expenditure was measured with indirect calorimetry. They performed four locomotor and four play activities in an exercise laboratory and were further measured during 12 minutes of a sports lesson. Validity evidence in relation to indirect calorimetry was examined with linear regression equations applied to the laboratory data. During the sports lessons predicted energy expenditure according to the regression equations was compared to measured energy expenditure with the Wilcoxon-signed rank test and the Spearman correlation. To compare the output, agreement between counts of the two monitors during the laboratory activities was assessed with Bland-Altman plots. The evidence of validity was similar for both monitors. Agreement between the output of the two monitors was good for vertical counts (mean bias = -14 ± 22 counts) but not for horizontal counts (-17 ± 32 counts). The current results indicate that the two accelerometer models are able to estimate energy expenditure of a range of physical activities equally well in young children. However, they show output differences for movement in the horizontal direction
DOI
10.24451/arbor.11085
https://doi.org/10.24451/arbor.11085
Publisher DOI
10.1080/1091367X.2013.805140
Journal or Serie
Measurement in Physical Education and Exercise Science
ISSN
1091-367X (Print) 1532-7841 (Online)
Publisher URL
https://www.tandfonline.com/doi/full/10.1080/1091367X.2013.805140
Related URL
https://www.tandfonline.com/doi/pdf/10.1080/1091367X.2013.805140?needAccess=true publication
Organization
EHSM - Leistungssport  
Monitoring  
Volume
17
Issue
3
Publisher
Taylor & Francis
Submitter
ServiceAccount
Citation apa
Jimmy, G., Seiler, R., & Mäder, U. (2013). Comparing the Validity and Output of the GT1M and GT3X Accelerometer in 5- to 9-Year-Old Children. In Measurement in Physical Education and Exercise Science (Vol. 17, Issue 3, pp. 236–248). Taylor & Francis. https://doi.org/10.24451/arbor.11085
File(s)
Loading...
Thumbnail Image

restricted

Name

Mäder_2013_Comparing the Validity and Output of the GT1M and GT3X Accelerometer in 5- to 9-Year Old Children.pdf

License
Publisher
Version
published
Size

446.92 KB

Format

Adobe PDF

Checksum (MD5)

652d51aa5aedefa864be6bbff79b7c95

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution