Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Arbitrary Waveform Multi-Lead Temporal Interference Stimulation
 

Arbitrary Waveform Multi-Lead Temporal Interference Stimulation

URI
https://arbor.bfh.ch/handle/arbor/46211
Version
Published
Identifiers
10.1109/EMBC58623.2025.11251769
Date Issued
2025-12-03
Author(s)
Geisshüsler, Lukas  
Kaufmann, Elisa Maria  
Piller, Julian
Haeberlin, Andreas
Niederhauser, Thomas  
Type
Conference Paper
Language
English
Abstract
Temporal interference stimulation (TIS) is used as a spatially selective tool for electrical deep brain stimulation in research applications. Despite its advantages over conventional stimulation methods, most of the current TIS systems are constrained by their reliance on only two leads and purely sinusoidal signals. Multi-lead and arbitrary waveform TIS may provide enhanced control over the stimulation location in a 2D plane or 3D space and the stimulation efficiency, respectively. This paper presents a novel therapeutic system for multi-lead arbitrary waveform TIS. The system uses a Direct Digital Synthesis (DDS) integrated circuit (IC) as a signal generator and a voltage-controlled constant current source, based on a Howland current pump, as an output stage to generate arbitrary signals. A frequency range from 100Hz to 1.5MHz (with a current gain of −3dB point at 1.5MHz into a 10kΩ load) and a current range from 0 to 80mA were achieved. This performance enables, for example, the generation of rectangular interference pulses with a duration of 10µs using five harmonics. This is a substantial increase over commonly used signal sources in TIS research, which typically operate at maximum frequencies between 20kHz and 400kHz. The system was evaluated in an in vitro experiment using a saline solution to characterize the interference patterns generated by three channels. The results obtained were in line with simulations and confirmed the system's capability to produce consistent and spatially precise temporal interference (TI) patterns in a 2D plane. Combined with the arbitrary waveform capacity, the system has high potential for advanced electrical therapies with TIS beyond deep brain stimulation, such as nerve, muscle, or cardiac stimulation.
Subjects
TK Electrical engineering. Electronics Nuclear engineering
Publisher DOI
10.1109/EMBC58623.2025.11251769
Journal
Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
ISSN
2694-0604
Publisher URL
https://ieeexplore.ieee.org/document/11251769
Organization
Technik und Informatik  
Institute for Human Centered Engineering (HUCE)  
HUCE / Labor für Mikroelektronik und Medical Devices  
Volume
2025
Project(s)
Temporal Interference Stimulation (TIS)
Conference
2025 47th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Publisher
IEEE
Submitter
Niederhauser, Thomas
Citation apa
Geisshüsler, L., Kaufmann, E. M., Piller, J., Haeberlin, A., & Niederhauser, T. (2025). Arbitrary Waveform Multi-Lead Temporal Interference Stimulation. In Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference (Vol. 2025). IEEE. https://arbor.bfh.ch/handle/arbor/46211
Contact us
Contact us
File(s)
Loading...
Thumbnail Image

open access

Name

Arbitrary_Waveform_Multi-Lead_Temporal_Interference_Stimulation.pdf

License
Attribution 4.0 International
Version
published
Size

2.02 MB

Format

Adobe PDF

Checksum (MD5)

ecde0111439e53f34c98b5d3ee2212f9

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution