  4. Electromyography of pelvic floor muscles with true differential versus faux differential electrode configuration
 

Electromyography of pelvic floor muscles with true differential versus faux differential electrode configuration

URI
https://arbor.bfh.ch/handle/arbor/41459
Version
Published
Date Issued
2020-10
Author(s)
Ballmer, Claudia
Eichelberger, Patric  
Leitner, Monika  
Moser, Helene
Luginbühl, Helena  
Kuhn, Annette
Radlinger, Lorenz  
Type
Article
Language
English
Subjects

Cross-correlation Mus...

Abstract
INTRODUCTION AND HYPOTHESIS

In pelvic floor muscle (PFM) electromyography (EMG) two different bipolar configurations are applied: "true differential" configuration (TD) measures neuromuscular activity with two ipsilateral electrodes, whereas "faux differential" configuration (FD) has two electrodes placed on each side of the PFMs. The aim of the study was to determine possible differences and the relationship between both configurations.

METHODS

A secondary data analysis of 28 continent (CON) and 22 stress urinary incontinent (SUI) women was performed. Surface EMG was measured using a vaginal probe during maximal voluntary (MVC) and fast voluntary (FVC) contractions. TD and FD were explored with amplitude- and time-related EMG parameters, cross-correlation coefficients (R(0)) and statistical parametric mapping (SPM).

RESULTS

Of a total of 62 comparisons of EMG parameters of MVC and FVC, only one comparison showed significant differences between the two configurations (CON group, FVC TD versus FD, p = 0.015). R(0) were high in both groups for all MVC and FVC variables (R(0) ≥ 0.989). SPM detected 3 out of 28 comparisons with short (0.124-0.404 s) significant supra-threshold clusters (p < 0.025).

CONCLUSIONS

The findings suggest that TD and FD might measure neuromuscular activity almost the same. Very high cross-correlation coefficients and a very limited number of significant results from EMG parameters, as well as SPM, suggest that in the measured sample the choice of TD or FD might remain practically irrelevant. To gain further insight into the scientific and clinical relevance of choosing either of the electrode configurations, the comparisons should be re-evaluated on a sample with more severe incontinence symptoms.
DOI
10.24451/arbor.13438
https://doi.org/10.24451/arbor.13438
Publisher DOI
10.1007/s00192-020-04225-4
Journal or Serie
International urogynecology journal
ISSN
1433-3023
Organization
Gesundheit  
Beckenboden und Kontinenz  
Volume
31
Issue
10
Publisher
Springer
Submitter
RadlingerL
Citation apa
Ballmer, C., Eichelberger, P., Leitner, M., Moser, H., Luginbühl, H., Kuhn, A., & Radlinger, L. (2020). Electromyography of pelvic floor muscles with true differential versus faux differential electrode configuration. In International urogynecology journal (Vol. 31, Issue 10, pp. 2051–2059). Springer. https://doi.org/10.24451/arbor.13438
File(s)
Loading...
Thumbnail Image

restricted

Name

Ballmer2020_Article_ElectromyographyOfPelvicFloorM.pdf

License
Publisher
Version
published
Size

589.05 KB

Format

Adobe PDF

Checksum (MD5)

593871464fbce2c95c5aef32eebb57b7

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution