Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Accuracy of prediction of maximum resistance at increased holding times based on a three seconds maximum static strength test of the three main strength elements on rings
 

Accuracy of prediction of maximum resistance at increased holding times based on a three seconds maximum static strength test of the three main strength elements on rings

URI
https://arbor.bfh.ch/handle/arbor/38150
Version
Published
Date Issued
2016
Author(s)
Schärer, Christoph
Hübner, Klaus  
Type
Article
Language
English
Subjects

Artistic gymnastics R...

Abstract
On rings in men’s artistic gymnastics, a high degree of relative maximum strength is crucial to present up to seven strength elements in the required quality in the routine. To increase this specific strength and strength endurance the coaches often prolong the holding times of those elements by using the devices counterweight and additional weight in training. The purpose of this study was to investigate the predictability of the maximum resistance (MR) (minimal counterweight/maximum additional weight) at five and seven seconds holding times based on the MR at three seconds of the elements Iron Cross (C), Support Scale (SS) and Swallow (S) and to provide coaches with a reliable conversion table that predicts the individual training weights at different holding times. Ten male gymnasts of the Swiss National Team performed a specific static MR-Test (three, five and seven seconds holding time) of the elements C, SS and S. The results showed a significant decrease in MR as holding time increased (t-Test: p < 0.001). The standard error of estimate (SEE) and explained variance (R2) revealed that the prediction of MR at five seconds (SEE 0.52 kg to 1.03 kg, R2 0.92 to 1.00) was more accurate than at seven seconds holding time (SEE 0.95 kg to 2.08 kg, R2 0.88 to 0.98). Based on the linear regression equations, a useful conversion table was established that predicts the MR at five and seven seconds holding time based on the three seconds MR at each of the tested elements.
DOI
10.24451/arbor.10945
https://doi.org/10.24451/arbor.10945
Journal or Serie
Science of Gymnastics Journal
ISSN
1855-7171
Publisher URL
https://www.fsp.uni-lj.si/en/research/scientific-magazines/science-of-gymnastics/previous-issues/2015102615453864/
Organization
Sportphysiologie Kraft  
Volume
8
Issue
2
Publisher
Univerza v Ljubljani, Fakulteta za Sport
Submitter
ServiceAccount
Citation apa
Schärer, C., & Hübner, K. (2016). Accuracy of prediction of maximum resistance at increased holding times based on a three seconds maximum static strength test of the three main strength elements on rings. In Science of Gymnastics Journal (Vol. 8, Issue 2). Univerza v Ljubljani, Fakulteta za Sport. https://doi.org/10.24451/arbor.10945
Note
Die Erlaubnis, diese PDF-Datei im ARBOR-Repository zu veröffentlichen, wurde eingeholt
File(s)
Loading...
Thumbnail Image
Download

open access

Name

Schärer_2016_Accuracy of prediction of maximum resistance at increased holding times based on a three seconds maximum static strength test of the three main strength elements on rings.pdf

License
Publisher
Version
published
Size

311.18 KB

Format

Adobe PDF

Checksum (MD5)

d09d0af650d3305682f4ae035bf60bd7

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution