Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Test-retest reliability and concurrent validity assessment of a novel high-frequency sensor device for anterior tibial translation measurement in loaded and unloaded condition: an exploratory cross-sectional study
 

Test-retest reliability and concurrent validity assessment of a novel high-frequency sensor device for anterior tibial translation measurement in loaded and unloaded condition: an exploratory cross-sectional study

URI
https://arbor.bfh.ch/handle/arbor/44505
Version
Published
Date Issued
2024-03-16
Author(s)
Deiss, Valentin  
Bähler, Philippe  
Kolly, Pascal
Schärer, Anton  
Henle, Philippe
Eichelberger, Patric  
Lutz, Nathanael
Baur, Heiner  
Type
Article
Language
English
Abstract
Background: Magnetic resonance imaging (MRI) and manual tests remain the standard for diagnosing anterior cruciate ligament (ACL) rupture. Furthermore, the passive knee displacement, also described as anterior tibial translation (ATT), is used in order to make decisions about surgery or to assess rehabilitation outcomes. Unfortunately, these manual tests are limited to passive situations, and their application to assess knee stability in loaded, weight-bearing positions are missing. Therefore, a new device with high-performance sensors and a new sensor setting was developed. The aim of this exploratory cross-sectional study was to assess the test-retest reliability of this new device in a first step and the concurrent validity in a second step.

Methods: A total of 20 healthy volunteers were measured. Measurement consistency of the new device was assessed on the basis of reliability during Lachman test setting and in loaded position by artificial knee perturbation in a test-retest procedure. In a second step, the concurrent validity was evaluated with the Lachmeter® as a reference instrument. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), the minimal detectable change (MDC) and Bland-Altman analysis were evaluated to assess the quality criteria.

Results: The measurements with the new device during the Lachman test provided a mean ATT of 5.46±2.22mm. The SEM ranged from 0.60 to 0.69mm resulting in an MDC between 1.67 and 1.93mm for the new device. In the loaded test situation, the mean ATT was 2.11±1.20mm, with test-retest reliability also showing good correlation (r>0.83). The comparison of the two measurement methods with an ICC of (r>0.89) showed good correlation, which also underlines the reasonable agreement of the Bland-Altman analysis.

Conclusions: The evaluation of the test-retest reliability of the new device during the knee stability testing in passive situation as well as in a functional, loaded situation presented good reliability. In addition, the new device demonstrated good agreement with the reference device and therefore good validity. Furthermore, the quality criteria demonstrated the ability of the new device to detect the cut-off value (3-5mm) described in the literature for the diagnosis of ACL-deficient knees, which underlines the clinical relevance of this new device as a reliable and valid tool.

Keywords: ACL injury; Anterior tibial translation; Functional joint stability; High frequency sensor device; Knee kinematics; Reproducibility of results.
Subjects
RC1200 Sports Medicine
DOI
https://doi.org/10.24451/dspace/11340
Publisher DOI
10.1186/s12891-024-07343-y
Journal or Serie
BMC Musculoskeletal Disorders
ISSN
1471-2474
Publisher URL
https://bmcmusculoskeletdisord.biomedcentral.com/articles/10.1186/s12891-024-07343-y
Related URL
https://pubmed.ncbi.nlm.nih.gov/38491405/
Organization
Gesundheit  
Physiotherapie  
Volume
25
Issue
1
Publisher
Springer
Submitter
Deiss, Valentin
Citation apa
Deiss, V., Bähler, P., Kolly, P., Schärer, A., Henle, P., Eichelberger, P., Lutz, N., & Baur, H. (2024). Test-retest reliability and concurrent validity assessment of a novel high-frequency sensor device for anterior tibial translation measurement in loaded and unloaded condition: an exploratory cross-sectional study. In BMC Musculoskeletal Disorders (Vol. 25, Issue 1). Springer. https://doi.org/10.24451/dspace/11340
File(s)
Loading...
Thumbnail Image
Download

open access

Name

BMC_deiss et al_2024.pdf

License
Attribution 4.0 International
Version
published
Size

1.82 MB

Format

Adobe PDF

Checksum (MD5)

e92369bc245f890f58b9e099ead90181

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution