Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Feedback control of heart rate during treadmill exercise based on a two-phase response model
 

Feedback control of heart rate during treadmill exercise based on a two-phase response model

URI
https://arbor.bfh.ch/handle/arbor/36681
Version
Published
Date Issued
2023
Author(s)
Wang, Hanjie  
Hunt, Kenneth James  
Type
Article
Language
English
Abstract
This work investigated automatic control of heart rate during treadmill exercise. The aim was to theoretically derive a generic feedback design strategy that achieves a constant input sensitivity function for linear, time-invariant plant models, and to empirically test whether a compensator C2 based on a second-order model is more dynamic and has better tracking accuracy than a compensator C1 based on a first-order model. Twenty-three healthy participants were tested using first and second order compensators, C1 and C2, respectively, during 35-minute bouts of constant heart rate treadmill running. It was found that compensator C2 was significantly more accurate, i.e. it had 7 % lower mean root-mean-square tracking error (1.98 vs. 2.13 beats per minute, p = 0.026), and significantly more dynamic, i.e. it had 17 % higher mean average control signal power (23.4 × 10−4 m2/s2 vs. 20.0 × 10−4 m2/s2, p = 0.011), than C1. This improvement likely stems from the substantially and significantly better fidelity of second-order models, compared to first order models, in line with classical descriptions of the different phases of the cardiac response to exercise. These outcomes, achieved using a treadmill, are consistent with previous observations for the cycle ergometer exercise modality. In summary, whenever heart rate tracking accuracy is of primary importance and a more dynamic control signal is acceptable, the use of a compensator based on a second-order nominal model is recommended.
Subjects
T Technology (General)
DOI
10.24451/arbor.20278
https://doi.org/10.24451/arbor.20278
Publisher DOI
10.1371/journal.pone.0292310
Journal
PLoS One
ISSN
1932-6203
Publisher URL
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0292310
Organization
Institute for Human Centered Engineering (HUCE)  
IRPT / Rehabilitationstechnik  
Technik und Informatk  
Institut für Rehabilitation und Leistungstechnologie IRPT  
Sponsors
Swiss National Science Foundation
Volume
18
Issue
10
Project(s)
Heart rate variability, dynamics and control during exercise
Publisher
Public Library of Science (PLoS)
Submitter
HuntK
Citation apa
Wang, H., & Hunt, K. J. (2023). Feedback control of heart rate during treadmill exercise based on a two-phase response model. In PLoS One (Vol. 18, Issue 10). Public Library of Science (PLoS). https://doi.org/10.24451/arbor.20278
File(s)
Loading...
Thumbnail Image

open access

Name

WanHun23b.pdf

License
Attribution 4.0 International
Version
published
Size

1.74 MB

Format

Adobe PDF

Checksum (MD5)

d2a498bd7fee32fbd90abae4ac61e5e0

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution