  4. A Direct-Digital 40 μA 100 kb/s Intracardiac Communication Receiver with 250 μs Startup Time for Low Duty-Cycle Leadless Pacemaker Synchronization
 

A Direct-Digital 40 μA 100 kb/s Intracardiac Communication Receiver with 250 μs Startup Time for Low Duty-Cycle Leadless Pacemaker Synchronization

URI
https://arbor.bfh.ch/handle/arbor/44555
Version
Published
Date Issued
2024-04-17
Author(s)
Ryser, Adrian  
Baeriswyl, Christof  
Moser, Michel Wenzel  
Burger, Jürgen  
Reichlin, Tobias
Niederhauser, Thomas  
Haeberlin, Andreas
Type
Article
Language
English
Abstract
The first commercial dual-chamber leadless pacemaker (LLPM) was introduced recently. The system combines two separate implants situated in the right atrium and the right ventricle of the heart. Implant synchronization is accomplished with conductive intracardiac communication (CIC) using the myocardium and blood as transmission channel. Successful implant synchronization of this dual-chamber LLPM has been demonstrated. However, the continuously active synchronization transceivers, consuming about 800 nA, cause a 25-45% reduction in the projected device longevity. This work proposes an alternative strategy for power-optimized LLPM synchronization, which is based on synchronous duty-cycling of the transceivers and direct-digital CIC (DD-CIC). In line with this strategy, a novel low-power DD-CIC receiver for short-packet communication based on Manchester-encoded data and with fast startup time is presented. The circuit was fabricated in 180 nm CMOS technology and analyzed with respect to sensitivity, current consumption and startup time under highly duty-cycled operation. The receiver achieves a sensitivity of 81.6±7.4 μV at a data rate of 100 kb/s, with an active current consumption of 39.1±0.6 μA and a startup time below 250 μs. Operating the receiver as specified by the proposed LLPM synchronization strategy reduces the current consumption to a measured average value of 73 nA. In conclusion, this work suggests synchronous duty-cycling for CIC-based implant synchronization as a promising concept to severely reduce the current consumption of contemporary dual-chamber LLPMs. Consequently, device longevity may be increased significantly, potentially reducing the frequency of costly and complication-prone re-interventions.
DOI
https://doi.org/10.24451/dspace/11376
Publisher DOI
10.1109/tbcas.2024.3390620
Journal or Serie
IEEE Transactions on Biomedical Circuits and Systems
Journal or Serie
IEEE Transactions on Biomedical Circuits and Systems
ISSN
1940-9990
Publisher URL
https://ieeexplore.ieee.org/document/10504651
Organization
Technik und Informatik  
Institute for Human Centered Engineering (HUCE)  
HUCE / Labor für Mikroelektronik und Medical Devices  
BFH-Zentrum Health Technologies  
Volume
18
Issue
6
Publisher
IEEE
Submitter
Niederhauser, Thomas
Citation apa
Ryser, A., Baeriswyl, C., Moser, M. W., Burger, J., Reichlin, T., Niederhauser, T., & Haeberlin, A. (2024). A Direct-Digital 40 μA 100 kb/s Intracardiac Communication Receiver with 250 μs Startup Time for Low Duty-Cycle Leadless Pacemaker Synchronization. In IEEE Transactions on Biomedical Circuits and Systems (Vol. 18, Issue 6, pp. 1338–1353). IEEE. https://doi.org/10.24451/dspace/11376
File(s)
Loading...
Thumbnail Image
Download

open access

Name

Ryser-2024-A_Direct-Digital_40_muA_100_kb_s_Intracardiac_Communication_Receiver_With_250_mus_Startup_Time_for_Low_Duty-Cycle_Leadless_Pacemaker_Synchronization.pdf

License
Attribution-NonCommercial-NoDerivatives 4.0 International
Version
published
Size

3.1 MB

Format

Adobe PDF

Checksum (MD5)

e9a2d63f3accab64dbe30c6ddc83a469

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution