Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. A rate-responsive duty-cycling protocol for leadless pacemaker synchronization
 

A rate-responsive duty-cycling protocol for leadless pacemaker synchronization

URI
https://arbor.bfh.ch/handle/arbor/44567
Version
Published
Date Issued
2024-08-19
Author(s)
Ryser, Adrian  
Reichlin, Tobias
Burger, Jürgen  
Niederhauser, Thomas  
Haeberlin, Andreas
Type
Article
Language
English
Abstract
Dual-chamber leadless pacemakers (LLPMs) consist of two implants, one in the right atrium and one in the right ventricle. Inter-device communication, required for atrioventricular (AV) synchrony, however, reduces the projected longevity of commercial dual-chamber LLPMs by 35–45%. This work analyzes the power-saving potential and the resulting impact on AV-synchrony for a novel LLPM synchronization protocol. Relevant parameters of the proposed window scheduling algorithm were optimized with system-level simulations investigating the resulting trade-off between transceiver current consumption and AV-synchrony. The parameter set included the algorithm’s setpoint for the target number of windows per cardiac cycle and the number of averaging cycles used in the window update calculation. The sensing inputs for the LLPM model were derived from human electrocardiogram recordings in the MIT-BIH Arrhythmia Database. Transceiver current consumption was estimated by combining the simulation results on the required communication resources with electrical measurements of a receiver microchip developed for LLPM synchronization in previous work. The performance ratio given by AV-synchrony divided by current consumption was maximized for a target of one window per cardiac cycle and three averaging cycles. Median transceiver current of both LLPMs combined was 166 nA (interquartile range: 152–183 nA) and median AV-synchrony was 92.5%. This corresponded to median reduction of 18.3% and 3.2% in current consumption and AV-synchrony, respectively, compared to a non-rate-responsive implementation of the same protocol, which prioritized maximum AV-synchrony. In conclusion, adopting a rate-responsive communication protocol may significantly increase device longevity of dual-chamber LLPMs without compromising AV-synchrony, potentially reducing the frequency of device replacements.
DOI
https://doi.org/10.24451/dspace/11385
Publisher DOI
10.1007/s13534-024-00413-z
Journal or Serie
Biomedical Engineering Letters
Journal or Serie
Biomedical Engineering Letters
ISSN
2093-985X
Publisher URL
https://doi.org/10.1007/s13534-024-00413-z
Organization
Technik und Informatik  
Institute for Human Centered Engineering (HUCE)  
HUCE / Labor für Mikroelektronik und Medical Devices  
BFH-Zentrum Health Technologies
Volume
14
Issue
6
Publisher
Springer Science and Business Media LLC
Submitter
Niederhauser, Thomas
Citation apa
Ryser, A., Reichlin, T., Burger, J., Niederhauser, T., & Haeberlin, A. (2024). A rate-responsive duty-cycling protocol for leadless pacemaker synchronization. In Biomedical Engineering Letters (Vol. 14, Issue 6). Springer Science and Business Media LLC. https://doi.org/10.24451/dspace/11385
File(s)
Loading...
Thumbnail Image
Download

open access

Name

s13534-024-00413-z.pdf

License
Attribution 4.0 International
Version
published
Size

1.16 MB

Format

Adobe PDF

Checksum (MD5)

292cb435bd4dcd8bfa62fada55380b6d

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution