Repository logo
  • English
  • Deutsch
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. CRIS
  3. Publication
  4. Technical feasibility of constant-load and high-intensity interval training for cardiopulmonary conditioning using a re-engineered dynamic leg press
 

Technical feasibility of constant-load and high-intensity interval training for cardiopulmonary conditioning using a re-engineered dynamic leg press

URI
https://arbor.bfh.ch/handle/arbor/40414
Version
Published
Date Issued
2019
Author(s)
Chrif, Farouk  
Nef, Tobias
Hunt, Kenneth James  
Type
Article
Language
English
Abstract
Background: Leg-press devices are one of the most widely used training tools for musculoskeletal strengthening of the lower-limbs, and have demonstrated important cardiopulmonary benefits for healthy and patient populations. Further engineering development was done on a dynamic leg-press for work-rate estimation by integrating force and motion sensors, power calculation and a visual feedback system for volitional work-rate control. This study aimed to assess the feasibility of the enhanced dynamic leg press for cardiopulmonary exercise training in constant-load training and high-intensity interval training. Five healthy participants aged 31.0 ± 3.9 years (mean ± standard deviation) performed two cardiopulmonary training sessions: constant-load training and high-intensity interval training. Participants carried out the training sessions at a work rate that corresponds to their first ventilatory threshold for constant-load training, and their second ventilatory threshold for high-intensity interval training.

Results: All participants tolerated both training protocols, and could complete the training sessions with no complications. Substantial cardiopulmonary responses were observed. The difference between mean oxygen uptake and target oxygen uptake was 0.07 ± 0.34 L/min (103 ±17%) during constant-load training, and 0.35 ± 0.66 L/min (113 ±27%) during high-intensity interval training. The difference between mean heart rate and target heart rate was −7 ± 19 bpm (94 ±15%) during constant-load training, and 4.2 ± 16 bpm (103 ±12%) during high-intensity interval training.

Conclusions: The enhanced dynamic leg press was found to be feasible for cardiopulmonary exercise training, and for exercise prescription for different training programmes based on the ventilatory thresholds.
Subjects
TA Engineering (General). Civil engineering (General)
DOI
10.24451/arbor.8705
https://doi.org/10.24451/arbor.8705
Publisher DOI
10.1186/s42490-019-0025-9
Journal
BMC Biomedical Engineering
ISSN
2524-4426
Publisher URL
https://doi.org/10.1186/s42490-019-0025-9
Organization
Institut für Rehabilitation und Leistungstechnologie IRPT  
BFH-Zentrum Technologien in Sport und Medizin  
Digital Health Lab  
Technik und Informatk  
BFH-Zentren  
Institut für Medizininformatik I4MI  
Volume
1
Issue
1
Submitter
HuntK
Citation apa
Chrif, F., Nef, T., & Hunt, K. J. (2019). Technical feasibility of constant-load and high-intensity interval training for cardiopulmonary conditioning using a re-engineered dynamic leg press. In BMC Biomedical Engineering (Vol. 1, Issue 1). https://doi.org/10.24451/arbor.8705
File(s)
Loading...
Thumbnail Image

open access

Name

ChrNefHun18a.pdf

License
Attribution 4.0 International
Version
published
Size

2.72 MB

Format

Adobe PDF

Checksum (MD5)

0639dc3f2de1ee9e2a7c73dec3f91778

About ARBOR

Built with DSpace-CRIS software - System hosted and mantained by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
  • Our institution